Honeywell


52118 products

Honeywell

V4944B1018/U

Honeywell

V4944B1026

Two Stage Pressure Regulating Gas Valve, 1 1/4", 120Vac, 3"-4.5" Water Column High Fire Regulator Setpoints, 3.5" Water Column Factory Setting, 0.8"-2" Low Fire Regulator Setpoints, 0.8" Water Column Factory Setting, Natural Gas, 480-1600 Cfh Capacity, 3-25 Second Valve Opening Time, 2 Second Maximum Valve CLosing Time, Straight Through, Non Offset, 1/8" Pilot Tapping, 1/2 Psi Pressure Rating, Upright Horizontal Mounting, Slow Opening, Two 5/16" Unf Bleed Tappings, -40-150 Degree Operating Temperature Range, Aluminum Body, 1/4" Spade Terminals with Three 30" Leadwires

Honeywell

V4944B1026/U

Honeywell

V4944B1034

1 1/2"AUTO COMB VLV 54"LDS 2ST

Honeywell

V4944B1042

2" 2STG LO=.8" HI=3.5" SloOpen

Honeywell

V4944B1059

Two Stage Pressure Regulating Gas Valve, 1", 120Vac, 3"-4.5" Water Column High Fire Regulator Setpoints, 3" Water Column Factory Setting, 0.8"-2" Low Fire Regulator Setpoints, 0.7" Water Column Factory Setting, Natural Gas, 300-1000 Cfh Capacity, 3-25 Second Valve Opening Time, 2 Second Maximum Valve CLosing Time, Straight Through, Non Offset, 1/8" Pilot Tapping, 1/2 Psi Pressure Rating, Upright Horizontal Mounting, Slow Opening, Two 5/16" Unf Bleed Tappings, -40-150 Degree Operating Temperature Range, Aluminum Body, 1/4" Spade Terminals with Three 30" Leadwires

Honeywell

V4944B1059/U

Honeywell

V4944B1075

Two Stage Pressure Regulating Gas Valve, 1", 120Vac, 3"-4.5" Water Column High Fire Regulator Setpoints, 3.5" Water Column Factory Setting, 1.6"-4" Low Fire Regulator Setpoints, 1.6" Water Column Factory Setting, Natural Gas, 300-1000 Cfh Capacity, 3-25 Second Valve Opening Time, 2 Second Maximum Valve CLosing Time, Straight Through, Non Offset, 1/8" Pilot Tapping, 1/2 Psi Pressure Rating, Upright Horizontal Mounting, Slow Opening, Two 5/16" Unf Bleed Tappings, -40-150 Degree Operating Temperature Range, Aluminum Body, 1/4" Spade Terminals

Honeywell

V4944B1075/U

Honeywell

V4944B1083

Two Stage Pressure Regulating Gas Valve, 1 1/4", 120Vac, 3"-4.5" Water Column High Fire Regulator Setpoints, 3.5" Water Column Factory Setting, 1.6"-4" Low Fire Regulator Setpoints, 1.6" Water Column Factory Setting, Natural Gas, 3-25 Second Valve Opening Time, 2 Second Maximum Valve CLosing Time, Straight Through, Non Offset, Two 5/16" Bleed Tappings, 1/2 Psi Pressure Rating, Upright Horizontal Mounting, Slow Opening, -40-150 Degree Operating Temperature Range, Aluminum Body, 1/4" Spade Terminals