|
|
Johnson Controls
EP2120S
|
|
|
|
Johnson Controls
EP2120S1
|
|
|
|
Johnson Controls
EP2121S1
|
|
|
|
Johnson Controls
EPC2
|
electric to pneumatic transducer which converts an analog input signal to a proportional pneumatic outpu modulating its control valve(s) to regulate the branch line pressure to the set point determined by the input signal. The EPC* offers four selectable input ranges of 0 to 0 to 1 0 to 15 VDC and 0 to 20 mA. Output pressure ranges are jumper shunt selectable for 0 to 1 0 to 15 and 0 to 20 psi and adjustable in all ranges. A 0-5 VDC feedback signal indicating the resultant branch line pressur is also provided. This signal varies linearly with branch pressure range selected. EPC's are designed with electrical terminals on one end and pneumatic connections on the othe allowing for maximum convenience in wiring and tubing installation when panel mounted. The EPC is a constant bleed interface with branch exhaust response time determined by the bleed orifice size and pressure differentials. If power fails to the EP it will continue to bleed through the bleed orifice until branch pressure is zero psig. Three way mixing valve control Pilot positioner control Compressor stagin Chiller loading
|
|
|
Johnson Controls
EPC2G
|
electric to pneumatic transducer which converts an analog input signal to a proportional pneumatic outpu modulating its control valve(s) to regulate the branch line pressure to the set point determined by the input signal. The EPC* offers four selectable input ranges of 0 to 0 to 1 0 to 15 VDC and 0 to 20 mA. Output pressure ranges are jumper shunt selectable for 0 to 1 0 to 15 and 0 to 20 psi and adjustable in all ranges. A 0-5 VDC feedback signal indicating the resultant branch line pressur is also provided. This signal varies linearly with branch pressure range selected. EPC's are designed with electrical terminals on one end and pneumatic connections on the othe allowing for maximum convenience in wiring and tubing installation when panel mounted. The EPC is a constant bleed interface with branch exhaust response time determined by the bleed orifice size and pressure differentials. If power fails to the EP it will continue to bleed through the bleed orifice until branch pressure is zero psig. Three way mixing valve control Pilot positioner control Compressor stagin Chiller loading
|
|
|
Johnson Controls
EPC2GB
|
E-P ENC NO BLEED GAUGE
|
|
|
Johnson Controls
EPC2GFS
|
E-P NO BLEED TRNSDCR;ORIDE GAG
|
|
|
Johnson Controls
EPC2GFSB
|
E/P TRANSDR BLD ON DEMAND
|
|
|
Johnson Controls
EPCG
|
ELECTRO-PNEU w/BLEED OVERRIDE
|
|
|
Johnson Controls
EPP-1000-11
|
E/P POSITIONER 5R & 8R
|