Resideo
4074EPM
|
Quick Connect to Rajah Adapter, Used with S8600 Family
|
|
|
Resideo
L6006C1034
|
HI/LO Limit Aquastat w/CirCtrl
|
|
|
Resideo
R7284B1024
|
Interrupted Electronic Oil Primary, Electrical Connections: Burner Motor, Oil Valve, Ignition, Cad Cell, Limit, Thermostat and Alarm, 15 Second Safety Switch Timing, Full Load Contact Ratings: 7.4 Amp @ 120Vac, 3.7 Amp @ 240Vac, Locked Rotor Contact Rating: 44.4 Amp @ 120Vac, 22.2 Amp @ 240Vac, Can be used with both Hydronic and Forced Air SystemsJunction Box on Main Burner Mounting, -40-147 Degree Temperature Range
|
|
|
Resideo
R7284P1080
|
Safety Switch
|
|
|
Resideo
R7284U1004
|
Interrupted Electronic Oil Primary, Electrical Connections: Burner Motor, Oil Valve, Ignition, Cad Cell, Limit, Thermostat and Alarm, Settable 15/30 or 45 Second Safety Switch Timing, Selectable Valve and Blower Delays and Two Line LCD Display,Full Load Contact Ratings: 7.4 Amp @ 120Vac, 3.7 Amp @ 240Vac, Locked Rotor Contact Rating: 44.4 Amp @ 120Vac, 22.2 Amp @ 240Vac, Can be used with both Hydronic and Forced Air SystemsJunction Box on Main Burner Mounting, -40-147 Degree Temperature Range
|
|
|
Resideo
R8182D1079
|
Combination Protectorelay and Hydronic Heating Controller, 120Vac, 45 Second Safety Switch Timing, 130-240 Degree High Limit Operating Range, 110-220 Degree Low Limit Operating Range, 10 Degree Fixed High Limit Differential, 10-25 Degree Adjustable Low Limit or Circulator, 1 1/2" Insulation Depth, Vertical Mount, 4.4 Amp @ 120Vac Full Load Electrical Rating, 26.4 Amp @ 120Vac Locked Rotar Electrical Rating, Includes Auxiliary ZC and ZR Terminals that may be used to provide Circulator Zone Control through an R845A, Also Includes Heat Conductive Compound and Vertical Case
|
|
|
Resideo
R8182H1070
|
Combination Protectorelay and Hydronic Heating Controller, 120Vac, 45 Second Safety Switch Timing, 130-240 Degree High Limit Operating Range, 110-220 Degree Low Limit Operating Range, 10 Degree Fixed High Limit Differential, 10-25 Degree Adjustable Low Limit or Circulator, 1 1/2" Insulation Depth, Junction Box Mount, 4.4 Amp @ 120Vac Full Load Electrical Rating, 26.4 Amp @ 120Vac Locked Rotar Electrical Rating, Includes Auxiliary ZC and ZR Terminals that may be used to provide Circulator Zone Control through an R845A, Also Includes Heat Conductive Compound and Vertical Case
|
|
|
Resideo
R8184G4009
|
Protectorelay Oil Burner Control, Controls Oil Burner, Oil Valve and the Ignition Transformer in Response to a Call for Heat, 45 Second Safety Switch Timing, With LED for Lockout Indication and Manual Trip Lever on Safety Switch to Assure Shutdown during servicing, Full Load Contact Ratings: 7.4 Amp @ 120Vac, 3.7 Amp @ 240Vac, Locked Rotor Contact Ratings: 44.4 Amp @ 120Vac, 22.2 Amp @ 240Vac, Pilot Duty Alarm Load Ratings: 75Va @ 120/240Vac, 25Va @ 24Vac, Resistive Alarm Load Ratings: 1.5 Amp @ 120/240Vac, 3 Amp @ 24Vac, -40-130 Degree Temperature Range
|
|
|
Resideo
R8184G4033
|
Protectorelay Oil Burner Control, Controls Oil Burner, Oil Valve and the Ignition Transformer in Response to a Call for Heat, 30 Second Safety Switch Timing, With LED for Lockout Indication and Manual Trip Lever on Safety Switch to Assure Shutdown during servicing, Full Load Contact Ratings: 7.4 Amp @ 120Vac, 3.7 Amp @ 240Vac, Locked Rotor Contact Ratings: 44.4 Amp @ 120Vac, 22.2 Amp @ 240Vac, Pilot Duty Alarm Load Ratings: 75Va @ 120/240Vac, 25Va @ 24Vac, Resistive Alarm Load Ratings: 1.5 Amp @
|
|
|
Resideo
R8184G4066
|
Protectorelay Oil Burner Control, Controls Oil Burner, Oil Valve and the Ignition Transformer in Response to a Call for Heat, 15 Second Safety Switch Timing, With LED for Lockout Indication and Manual Trip Lever on Safety Switch to Assure Shutdown during servicing, Full Load Contact Ratings: 7.4 Amp @ 120Vac, 3.7 Amp @ 240Vac, Locked Rotor Contact Ratings: 44.4 Amp @ 120Vac, 22.2 Amp @ 240Vac, Pilot Duty Alarm Load Ratings: 75Va @ 120/240Vac, 25Va @ 24Vac, Resistive Alarm Load Ratings: 1.5 Amp @ 120/240Vac, 3 Amp @ 24Vac, -40-130 Degree Temperature Range
|