|
|
Resideo
R845A1030
|
Hydronic Switching Relay, 120V Primary Power Supply, 24Vac Coil Rating, Double Pole Single Throw ( DPST ) Switching Action One Pole Line Voltage One Pole Low Voltage, Enclosed Intermediate Relays for 24V Two or Three Wire Thermostats, Includes Integral Transformer and Enclosure
|
|
|
Resideo
R847A1085
|
Heavy Duty Relay, 120Vac Primary Voltage, DPST or SPST Switching Action, 2 Wire, Full Load Contact Ratings: 22 Amp @ 120Vac, 10 Amp @ 240Vac, Locked Rotor Contact Ratings: 100 Amp @ 120Vac, 50 Amp @ 240Vac, Includes Integral Transformer and Enclosure
|
|
|
Resideo
R8845U1003
|
Universal Switching Relay, 120Vac Primary Voltage, Two SPST Switches plus PowerPile Rated Low Voltage SPST Relay ( If Normally Closed Contacts are Needed Use RA889A Series ), 2 or 3 Wire Thermostat Control of Line Voltage Devices, 7.4 Amps Full Load @ 120Vac, 44.4 Amps Locked Rotor @ 120Vac, -20-120 Ambient Temperature Range, 0-90% RH Non Condensing Operating Humidity Range
|
|
|
Resideo
RA832A1066
|
Switching Relay, 120 Vac Input, 24 Vac Coil Rating, DPST, One Pole Line Voltage, Other Pole Low Voltage or Millivolt, 2 Wire Control Circuit, Includes Integral Transformer and Cover
|
|
|
Resideo
RA832A1074
|
Switching Relay, 240 Vac Input, 24 Vac Coil Rating, DPST, One Pole Line Voltage, Other Pole Low Voltage or Millivolt, 2 Wire Control Circuit, Includes Integral Transformer and Cover
|
|
|
Resideo
RA832A1082
|
Switching Relay, 240 Vac Input, 24 Vac Coil Rating, DPST, One Pole Line Voltage, Other Pole Low Voltage or Millivolt, 2 Wire Control Circuit, Includes Integral Transformer and Cover
|
|
|
Resideo
RA889A1001
|
Switching Relay, 120Vac Primary Voltage, SPDT plsu PowerPile Rated Low Voltage SPST Relay, Push to Test Button, 24Vac Transformer Secondary Rating, 0.12 Amp Thermostat Heat Anticipator Setting, 15 Amp @ 120Vac Full Load Contact Rating, 30 Amp Locked Rotor @ 120Vac, -20-120 Ambient Temperature Rating, 0-90% RH Non Condensing Operating Humidity Range, Includes Integral Transformer and Enclosure
|
|
|
Resideo
RA89A1074
|
Hydronic Switching Relay, 120Vac Primary Voltage, 24Vac Coil, SPST Switching Action, Provides Intermediate Switching of a Line Voltage Device from a Low Voltage Controller, Includes Integral Transformer and Enclosure
|
|
|
Resideo
RA89A1116
|
SwitchingRelayW/Int.Transfmr
|
|
|
Resideo
RC840
|
Electromechanical Relay, Inout Voltage: 120 Vac, 208 Vac, 240 Vac, 277 Vac, 347 Vac, 24V/40 mA/1 VA Control Signal, -4-140 Degree Temperature Rating, On/ Off Switching, Compatible with 24 V 2 or 3 Wire Thermostats
|