Resideo


2269 products

Resideo

R841D1036

Electronic Heating Relay, 24Vac Coil Rating, SPST Switching, Full Load Contact Ratings: 7 Amp @ 208/240/277Vac, 14 Amp @ 120Vac, Locked Rotor Contact Ratings: 42 Amp @ 208/240/277Vac, 84 Amp @ 451Vac, Resistive Contact Ratings: 22 Amp @ 120/208/240Vac, 19 Amp @ 277Vac, Includes Enclosure with Conduit Bushing

Resideo

R845A1030

Hydronic Switching Relay, 120V Primary Power Supply, 24Vac Coil Rating, Double Pole Single Throw ( DPST ) Switching Action One Pole Line Voltage One Pole Low Voltage, Enclosed Intermediate Relays for 24V Two or Three Wire Thermostats, Includes Integral Transformer and Enclosure

Resideo

R847A1085

Heavy Duty Relay, 120Vac Primary Voltage, DPST or SPST Switching Action, 2 Wire, Full Load Contact Ratings: 22 Amp @ 120Vac, 10 Amp @ 240Vac, Locked Rotor Contact Ratings: 100 Amp @ 120Vac, 50 Amp @ 240Vac, Includes Integral Transformer and Enclosure

Resideo

R8845U1003

Universal Switching Relay, 120Vac Primary Voltage, Two SPST Switches plus PowerPile Rated Low Voltage SPST Relay ( If Normally Closed Contacts are Needed Use RA889A Series ), 2 or 3 Wire Thermostat Control of Line Voltage Devices, 7.4 Amps Full Load @ 120Vac, 44.4 Amps Locked Rotor @ 120Vac, -20-120 Ambient Temperature Range, 0-90% RH Non Condensing Operating Humidity Range

Resideo

RA832A1066

Switching Relay, 120 Vac Input, 24 Vac Coil Rating, DPST, One Pole Line Voltage, Other Pole Low Voltage or Millivolt, 2 Wire Control Circuit, Includes Integral Transformer and Cover

Resideo

RA832A1074

Switching Relay, 240 Vac Input, 24 Vac Coil Rating, DPST, One Pole Line Voltage, Other Pole Low Voltage or Millivolt, 2 Wire Control Circuit, Includes Integral Transformer and Cover

Resideo

RA832A1082

Switching Relay, 240 Vac Input, 24 Vac Coil Rating, DPST, One Pole Line Voltage, Other Pole Low Voltage or Millivolt, 2 Wire Control Circuit, Includes Integral Transformer and Cover

Resideo

RA889A1001

Switching Relay, 120Vac Primary Voltage, SPDT plsu PowerPile Rated Low Voltage SPST Relay, Push to Test Button, 24Vac Transformer Secondary Rating, 0.12 Amp Thermostat Heat Anticipator Setting, 15 Amp @ 120Vac Full Load Contact Rating, 30 Amp Locked Rotor @ 120Vac, -20-120 Ambient Temperature Rating, 0-90% RH Non Condensing Operating Humidity Range, Includes Integral Transformer and Enclosure

Resideo

RA89A1074

Hydronic Switching Relay, 120Vac Primary Voltage, 24Vac Coil, SPST Switching Action, Provides Intermediate Switching of a Line Voltage Device from a Low Voltage Controller, Includes Integral Transformer and Enclosure

Resideo

RA89A1116

SwitchingRelayW/Int.Transfmr